Sample report · Template standard · CC-SAMPLE-001

Residential building inspection

Clear findings. Defensible evidence. Practical next steps.

A premium report format for Code Comply inspections, designed to make risk, evidence, standards context and recommendations easy to understand.

Overall ratingFurther advice
Total findings8
Major defects2
Safety items1
Inspection profile

Inspection details

Visual, non-invasive assessment
InspectorRonak Patel
Contact0432 713 785
Emailinfo@codecomply.com.au
WeatherDry, clear access
Decision summary

Executive summary

Highest priority items first
Report positionReview

Specialist advice is recommended before relying on the affected areas as sound or watertight.

Major2

Likely to require qualified assessment or repair.

Minor4

Maintenance or monitoring items.

Safety1

Prompt action recommended.

Template intent: keep the client focused on what matters. The report should lead with risk, then support each finding with evidence, room/location, reference context and a practical recommendation.

Risk register

Priority findings

Summary table for fast review
PriorityAreaFindingReference / contextRecommended action
MajorMaster bedroom ceilingWater staining consistent with possible roof or flashing leak above.NCC/BCA weatherproofing principles; AS 4349.1 reporting context.Engage a licensed roofer to investigate and repair the source before internal make-good.
MajorWestern exterior wallCracking measured up to approximately 7mm with visible displacement.AS 2870 movement/crack assessment guidance.Obtain structural engineer advice and monitor movement.
SafetySubfloor access areaEvidence of timber pest activity and damaged subfloor members.AS 3660 termite management context.Arrange pest inspection/treatment and carpenter/engineer review of affected members.
Evidence-led observations

Detailed findings

Each item linked to photo/video evidence
01

Master bedroom ceiling — water staining

Major

Localised staining was observed to the plasterboard ceiling. The pattern is consistent with moisture entry above this area. No invasive testing was undertaken.

Recommendation: inspect roof coverings, flashings, penetrations and drainage paths above this location before internal make-good works.
Evidence placeholderCeiling staining photograph
02

Western elevation — external cracking

Major

Cracking was noted to the western external wall. The largest visible crack was approximately 7mm. The cause cannot be confirmed from a visual inspection alone.

Recommendation: obtain structural engineer advice and consider monitoring for progressive movement.
Evidence placeholderExternal wall crack photograph
03

Subfloor — timber pest evidence

Safety

Visible damage was observed to accessible subfloor timbers. Extent and activity status require specialist confirmation.

Recommendation: arrange timber pest inspection and repair assessment before occupation or major works.
Evidence placeholderSubfloor timber photograph
Inspection trail

Room-by-room record

  • Entry / hallway — no major defects observed.
  • Kitchen — sealant deterioration at splashback junction.
  • Bathroom — grout cracking near shower hob.
  • Garage — hairline slab cracking to monitor.
Evidence register

Captured evidence

  • Walkthrough video for general room condition.
  • Targeted photographs for each major finding.
  • Inspector notes retained against each area.
  • Specialist referral items flagged for follow-up.
Important scope note

Scope and limitations

This report is based on a visual inspection of reasonably accessible areas at the time of inspection. It does not include destructive, invasive or specialist testing. Concealed defects, inaccessible areas, latent conditions and services not safely available for inspection may not be identified.

Where a specialist recommendation is made, the client should obtain that advice before making a purchase, settlement, rectification or occupancy decision.

Declaration

Inspector declaration

I declare that this inspection was conducted as a visual building inspection within the stated scope and limitations. The observations and recommendations reflect the conditions visible at the time of inspection.

Inspector signature
Date